Ultrasonic Flowmeter TDS-100F dengan M2 Transducer DN50-700mm

Ultrasonic Flowmeter TDS-100F dengan M2 Transducer DN50-700mm

Liquid Flow Meter adalah alat untuk mengukur laju aliran atau jumlah suatu fluida yang bergerak mengalir.
Jenis cairan yang diukur oleh flow meter bisa berbagai macam cairan seperti air minum, air limbah, air lumpur, susu, cairan kimia, air gula, alkohol, oli dll
Ultrasonic Flow Meter TDS-100F mengukur laju aliran cairan dengan metode ultrasonik. Memiliki kelas proteksi unit yang kedap air IP65.

Specification:
Linearity : Better than ±1%.
Accuracy : ±1% of reading at rates >0.6 ft/s (0.2m/s). Assume a fully developed flow profile.
Repeatability : ±0.2%.
Velocity :
±0.03 ~ ±105 ft/s
(±0.01 ~ ±30 m/s), bi-directional
Measurement Period : 0.5s
Display : LCD with backlight. 2×20 letters.
Keypad : 4×4-key membrane keypad with
tactile feedback : Units
English (U.S.) or metric.
Outputs : Analogue output: 4-20mA or 0-20mA current output. Impedance 0~1kW. Accuracy 0.1%. .
Isolated OCT output: for frequency output (0~9,999Hz), alarm driver, or totaliser pulse output, ON/OFF control, etc.
Relay output 1A@125VAC or 2A@30VDC. For ON/OFF control, alarm driver, totaliser output, etc.
Internal Alarm (Buzzer): user programmable.
External Alarm Driver: alarm signal can be transmitted to Relay or OCT output terminals to drive an external alarm.
RS-232 serial port.

Input :
Five channel 4-20mA current inputs for signals such as temperature, pressure, liquid level, and etc.. Accuracy 0.1%.
Two of the five input channels are wired to terminal blocks. The remaining three channels are optional.
Enclosure : Die-cast aluminum enclosure.
Protection Class: IP65 (NEMA 4X).
Size: 9.88×7.56×3.15 (251x192x80mm3) for standard version
Clamp-on :
S2-type: for pipe size (DN15~DN100mm)
M2-type: for pipe size (DN50~DN700mm)
L2-type: for pipe size (DN300~DN6,000mm)

 

Liquid Types :
Virtually all commonly used clean liquids.
Liquids with small quantity of tiny particles may also be applicable. Particle size should be less than 75um, particle concentration less than 10,000ppm.
Liquids should contain no or very minor air bubbles.
Examples are chilled/hot water, sea water, waste water, chemical liquids, oil, crude oil, alcohol, beer, etc.
Liquid Temp :
(0C – 160C) for clamp-on transducer. Higher temperatures can be accommodated. Consult us for assistance.
(0C – 160C) for wetted transducer.
Pipe Size : 1 ~ 240 (DN15mm ~ DN6,000mm).
Pipe Material : All metals, most plastics, fiber glass, etc. Allow pipe liner.
Cable : Shielded transducer cable. Standard length 15 (5m). Can be extended to 1640 (500m). Contact us for longer cable requirement.
Power :
AC: 240V DC: 8VDC~36VDC
Power consumption: < 2W
Weight : Standard main unit: 6.6lb (3kg)

 

 

Untuk Informasi Lebih Lengkap,
Hubungi: 081278641546/081382704268
alatuji-karyamitra.indonetwork.co.id
www.mesinpertanians.com
www.alatuji.net
alatsafety-murah.blogspot.com
pabrikasimesin.blogspot.com

Tinggalkan Balasan

Alamat email Anda tidak akan dipublikasikan. Ruas yang wajib ditandai *

Buka Obrolan
Butuh Bantuan?